SE5124/SE5224 Series

4-port RS-485/422 Device Servers with Digital I/Os and Analog

Provide 4-channel RS-485/422 serial ports
Baud rate: 300~460800 bps
Dual-LAN Redundancy
Conform to TCP/IP, UDP, ARP, ICMP, HTTP and TFTP Client protocols
Support TCP server, TCP client and UDP transmission modes
Support Web management
4 digital I/Os to collect local data for status monitoring
2 channels 4-20mA Signal Converters
Low-power consumption design
Metal housing with IP40 and high level EMC protection
Support  wide  voltage 12~48V DC power input
Overview Specifications Models
Overview

4-port RS-485/422 Device Servers with Digital I/Os and Analog

SE5124/SE5224 Series are serial device servers that can make serial device be equipped with networking capability instantly and centrally manage the scattered serial devices and hosts via network. This product supports 4 RS-485/422 combo serial ports to 2 100M Ethernet copper ports which supports electromagnetic isolation. It adopts DIN-Rail or wall mounting to meet the requirements of different application scenes.

SE5124/SE5224 Series support multiple network protocols, such as TCP, UDP, TELNET, ARP, ICMP, HTTP, DNS and DHCP protocol. It also possesses complete management functions, including Access Control, Rapid Configuration, Online Upgrading and so on. Each serial port supports 4 TCP or UDP session connections, and it also supports TCP Server, TCP Client, UDP Server and UDP Client operating modes and Telnet , Web access modes. 
SE5124/SE5224 provide 2 10/100Base-T (x) RJ45 ports and 4-channel RS-485 serial ports. It has two separate LAN ports that can be connected to separate LAN networks. Dual-LAN redundancy involves setting up two separate physical networks to connect the PC host with the SE5124/SE5224 (the PC host also requires two LAN cards). If one connection fails, the PC host can still communicate with your serial devices over the alternative LAN connection.

Hardware adopts fanless, low power consumption, wide temperature and voltage design and has passed rigorous industrial standard tests, which can suit for the industrial scene environment with harsh requirements for EMC. It can be widely used in PLC control and management, Building Automation System, Health Care Automation System, measuring instrument and environmental forces monitoring system.

SE5124/SE5224 Series have built-in digital I/Os, provide maximum flexibility when you need to integrate serial equipment in the field with an Ethernet network. The combination of digital I/Os makes the device servers well-suited for a variety of industrial data acquisition applications. The DI/Os on the device can be controlled over TCP/IP using the Modbus TCP protocol and can be configured from a web browser.
SE5124/SE5224 Series products realize the signal acquisition between sensor and host, to measure analog signals. The products can be applied to RS-232/485 bus industrial automation control system, 4-20mA signal measurement, monitoring and control small-signal measurement and signal isolation and long-term industrial transmission and so on. Products include power supply isolation, signal isolation, linearization, A/D conversion and RS-485 serial communication. 

Specifications

4-port RS-485/422 Device Servers with Digital I/Os and Analog

Ethernet
Standard: 10Base-T, 100Base-TX
Rate: 10/100M Automatic Flow Control, MDI/MDI-X Autotunning
Interface quantity: 2
Interface form: RJ45
Duplex mode: Full/Half Duplex Mode Self-adaptive

Protocol: TCP, UDP, ARP, HTTP, ICMP, DHCP, DNS
Operating mode: TCP Server, TCP Client, UDP Server, UDP Client
Serial Port
Standard: RS-485/422
RS-422 signal:TX+,TX-, RX+, RX-, GND
RS-485 signal: D+, D-, GND
Check digit: None, Even, ODD
Data bits: 5bit, 6bit, 7bit, 8bit
Stop bit: 1bit, 2bit
Baud rate: 300~460800bps
Directional control: RS-485 adopts data flow auto control technology
Load capacity: RS-485/422 side supports 32 point polling environment (customizable 128 points)
Interface form: RS-485/422 and adopts5-bit 3.84mm pitch terminal blocks
Analog signal interface
2 channel 4-20mA current signal input
12-bit AD converter, testing accuracy >0.1%

Update rates 1K~2KHz
Input resistance 120Ω

Digital Outputs
Independent 2 channels output
Dry contacts: Short circuit or Open
Relay output form: FORM C (SPDT)
Relay-operating time 6ms
Relay release time 3ms
Total switch time 10ms
Relay contacts capacity 2A/24VDC
The maximum working switch frequency: 50Hz
Digital Inputs
Independent 2 channels input
Dry contact Input  
On: short to GND
Off: open

Indicator
Power supply indicator, Ethernet port indicator, serial port indicator
Power Supply Wide DC power input 12~48VDC (12V/24V/48V typical)
7.62mm industrial terminal block

No-load Consumption:< 1.2W (@24VDC)
Full-load Consumption:< 1.68W (@24VDC)
Mechanical Properties Dimension(W×H×D): 40mm×128mm×103mm
Net weight: 430g
Housing: Metal, IP40 protection
Installation: DIN rail mounting

Environmental 

Working temperature:-40℃~85℃
Storage temperature: -40℃~ 85℃
Relative humidity: 5% ~ 95% (no condensing) 

Industrial Standard

IEC61000-4-2(ESD):±8KV Contact, ±15KV Air
IEC61000-4-3(RS):10V/M(80-1000MHZ)
IEC61000-4-4(EFT):Power ±4KV, Data Cable ±4KV
IEC61000-4-5(Surge):Power ±4KV CM/ ±1KV DM, Data Cable±4KV
IEC61000-4-6(CS):3V (10KHZ-150KHZ), 10V (150KHZ-80MHZ)
IEC61000-4-16(MS):30V COUNT 300V, 1S
IEC60068-2-6(Vibration)
IEC60068-2-27(Shock)
IEC60068-2-32(Free Fall)
IEC61000-6-2(General Industrial Standard)
Warranty 5 years
Models



Available Models

100M Copper Port

100M Fiber Port

RS-485/422

SE5124

2

1

4

 SE5224 

2

 2 

 4